Part Number Hot Search : 
C68HC11 RP421 2SB628 MB91F 2SK893 6387XS24 MCT7800 ML482403
Product Description
Full Text Search
 

To Download 5500204 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 EMC-Power Line Filters for 1-Phase Systems
FMLB Series, all-purpose filters to Protection Class I, conform to EN 133200, UL 1283 and IEC 60950
Nominal current: Rated voltage UR (Umax): Attenuation: Leakage current: Test voltages: Climatic category: 50% saturation typ.: Inrush current: MTBF @ 40 C / UR (Umax): * without resistor 6 - 20 A @ 40 C 125/250 VAC 50/60 Hz Standard for Standard and Medical applications L/N E 2.7 kVDC, 2 sec L N 1.7 kVDC, 2 sec * 25/100/21 acc. to IEC 60068-1 2 to 3 x IN @ 20 C 1.5 x IN 1 min. per hour > 200'000 h acc. To MIL-HB-217 F
Standard and Medical Versions
The SCHURTER filter family has been specially developed for universal industrial applications such as: * Control systems * Power supplies * Stepper motor drives * Power converters International approvals center (i.e. UL) today demand high filter performance with regard to attenuation and loading characteristics. During the design, special considerations were made for applications that require high attenuation at the specified maximum load or where asymmetrical loading of the filter occur independently from line impedance at the installation site. The implemented filter range wholly conforms to the requirements of the international standards EN 133200, UL 1283 and IEC 60950 and is ideally suited for applications with EN 55011, EN 55014and EN 55022 requirements.
Order Numbers and Technical Data Type FMLB Standard 5500.2035 5500.2036 5500.2037 5500.2038 Type FMLB Medical M5 5500.2082 5500.2083 5500.2084 5500.2085 IN (1) @ a 40 C [A] 6 10 16 20 IN (1) @ a 40 C [A] 6 10 16 20 UR (Umax) [VAC] 250 250 250 250 UR (Umax) [VAC] 250 250 250 250 LN (2) -30% / +50% [mH] 2 2 2 2 x 14.0 x 5.0 x 2.0 x 1.5
* Version with quick connect terminals (flat pins, 6.3 x 0.8 mm) is produced as standard series. * Key features of the high-current filter series: - simple, space-saving installation - excellent price/performance ratio - good common mode attenuation characteristics (from 10 kHz to 300 MHz) * To maximize the filter performance, the following EMC rules should be considered: - physical separation of filter input and output lines - physical separation of the interference source itself Optional versions: * Version with cable connections in place of the quick connect terminals * Medical version M80* with leakage current < 80A
*Contact Schurter for minimum order quantity
Leakage current (3) @ 250 V / 50 Hz [mA] < < < < 0.35 0.35 0.35 0.35
Cx(X2) [F] 0.1 0.1 0.1 0.1 Cx(X2) [F] 0.1 0.1 0.1 0.1
Cy(Y2) [nF] 3.3 3.3 3.3 3.3 Cy(Y2) [nF] -
R [M] R [M] 1 1 1 1
Case
49 49 49 49 Case
LN (2) -30% / +50% [mH] 2 2 2 2 x 14.0 x 5.0 x 2.0 x 1.5
Leakage current (3) @ 250 V / 50 Hz [A] < < < < 5 5 5 5
49 49 49 49
(1) Current derating over 40C : I = IN x (100-a)/60 (2) Nominal inductance measured according to EN 138100, see introduction of this catalog, paragraph 3.4 (3) Measured according to IEC 60950 5.2.3 Annex D, see introduction of this catalog, paragraph 3.5
Versions with connecting cables are available on request: min. order 100 pieces.
Case 49
Circuit diagram
Insertion loss Standard
Insertion loss Medical M5
24
www.schurterinc.com


▲Up To Search▲   

 
Price & Availability of 5500204

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X